Chromatography Services Laboratory
|
![]() |
The Chromatography Services Laboratory offers a number of Gas Liquid Chromatographs and High Performance Liquid Chromatographs to suit semi-preparative or analytical separation of chemical compounds. The chromatographic runs are performed by the research analyst with the assistance of the lab manager, Mr Victor De Guzman, who can provide advice on instrument operation, hands-on training and safety.
This service is provided to the School of Chemistry, Centre for Green Chemistry, other Monash Faculties and external commercial clients. Charges for chromatographic analysis are negotiated on an individual basis. Priority access is given to research staff and post-graduate students during school terms. The facility provides generic columns for routine analytical applications however, in some cases, specialized columns for non-routine chromatographic applications need to be supplied by the analyst.
School of Chemistry, Clayton Campus
Location: Bldg 23, room 48
Phone: +613 9905 4584
Fax: +613 9905 4597
Mobile: 0411 703 802
Legend: FID = Flame Ionization Detector; TCD = Thermal Conductivity Detector
|
Code |
Brand & Model |
Detector |
Column Type |
Application |
|---|---|---|---|---|
|
GLC 1 |
Varian 3700 Manual Injection |
FID |
A: 6’ X ¼” 10% SE30 B: 30mx0.25mmx0.12um BPX5 (SGE) |
A: Pack column for neat samples B: Capillary column for trace analysis of non polar compounds |
|
GLC 2 |
HP 5890 Manual Injection |
FID |
50mx0.25mmx0.12um e.g.XE-60-S-VAL-S-A-PEA |
Trace analysis of chiral compounds (Supply own column) |
|
GLC 3 |
Varian 3700 Manual Injection |
FID |
A: 12QC5 BP20 B: 6’x1/4” 10% Carbowax 20M on AWDMCS |
A: Capillary column for trace analysis of polar compounds B: Pack column for neat polar samples |
|
GLC 4 |
Varian 3700 Manual Valve Injection |
TCD / FID |
A: 6’x1/4: Poropak Q / Molecular sieve B: C-18 Porasil |
A: Pack column for gas analysis of permanent gases. B: Pack column for Hydrocarbons (C1-C5) |
|
GLC 5 |
Agilent 6850 Auto Sampler |
FID |
30mx0.32mmx0.25um J&W HP-1 |
Capillary column for trace analysis of non polar compounds to intermediate compounds |
|
GLC 6 |
Agilent 6850 Auto Sampler |
FID |
30mx0.32mmx0.25um J&W HP-1 |
Capillary column for trace analysis of non polar compounds to intermediate compounds |
|
GLC 7 |
Shimadzu GC8A Manual Injection |
FID |
50m x0.53mm CP AL2O3 / KCL |
Capillary column for trace analysis of volatile compounds |
Legend: ELSD = Evaporative Light Scattering Detector, PDA = Photo Diode Detector, UV = Ultraviolet detector
|
Code |
Brand & Model |
Detector |
Column Type |
Application |
|
|---|---|---|---|---|---|
LC 1 |
Agilent 1200 RR Auto sampler |
PDA |
4mmx150mm 5um |
Reverse phase rapid resolution separations or Normal phase chiral separations |
|
LC 2 |
Waters 6000A |
Variable UV/VIS |
Semi-preparative or analytical reverse phase columns |
|
|
LC 3 |
Waters 600 |
PDA |
Reverse phase separation in analytical mode |
|
|
LC 4 |
Agilent 1200 Auto sampler |
PDA |
Reverse phase separation in analytical mode |
Reverse phase in Quarternary gradient elution or Isocratic runs with PDA detector |
|
LC 5 |
Agilent 1200 Auto sampler |
PDA / ELSD |
Reverse phase or GPC separation in analytical mode |
Reverse phase in quaternary gradient elution or Isocratic Size exclusion runs with PDA detector and ELSD. |